Electric Height Adjustable Base Stand
Features:
1. Heavy load and smart balance
2. Smooth running speed and low noise
3. Concise and easy with nice appearance
4. Low maintenance cost
5. Easy to install and disassemble
6. Max Adjustable Route 400mm
7. Width adjustable is customized
8. Multipurpose for laboratory apparatus
Technical Parameters:
Max Route(mm) | 100 | 150 | 200 | 250 | 300 | 350 | 400 |
Height of Min. Height(mm) | 440 | 490 | 540 | 590 | 640 | 690 | 740 |
Base Stand Max. Height(mm) | 540 | 640 | 740 | 840 | 940 | 1040 | 1140 |
Max Load | 400kg | ||||||
Load Speed | 5mm/s | ||||||
Working Frequency | 10%, max continuous working time is 2 minutes | ||||||
Noise | <65dB | ||||||
Working Temperature | -26℃~65℃ | ||||||
Material | Pedestal: 3.0mm steel Lifting Rod: Aluminum alloy |
||||||
Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | ||||||
Controller Consumption | 100~200W | ||||||
Caster | Footmaster caster | ||||||
Applications | For biosafety cabinet, laminar flow cabinet, fume hood and other laboratory equipment |
Air Velocity Meter
1. Measurement Range: 0~30m/s
2. Accuracy: ±3% or ±0.015m/s
3. Resolution: 0.01m/s
4. Data log 12, 700+samples and 100 test IDs
5. The 9535 model comes with a telescopic straight probe
6. The 9535-A model comes with an articulated probe
Dust Particle Counter
1. Particle Size Channel: 0.3, 0.5, 1.0, 3.0, 5.0, 10.0(μm)
2. Sampling Period: 1~9999s
3. Number of Sampling Points: 2~9
4. Sampling Frequency: 2~9
5. Sampling Quantity: 2.83L/min(0.1cfm)
Digital Sound Level Meter
1. Measurement Range: 30~130dB
2. Accuracy: ±1.5dB
3. Resolution: 0.1dB
Illumination Meter
1. Light Intensity Range: 0~200, 000LUX
2. Accuracy:Â
±3%rdg±0.5%fs(<10,000lux)
±4%rdg±10dgts(>10,000lux)
Infrared Sterilizer
Two types:
HWQ-001: 36mm dimension of cavity
HWQ-002: 22mm dimension of cavity
1. Central High-temperature: 930℃±30℃
2. Heat-up Time: 20minÂ
3. Size: 150*95*210mm
4. Package Size(W*D*H): 266*225*145mm
5. Weight: 1600gÂ
6. Power: 180W
7. Voltage: 110/220V, 50/60Hz
Foot Rest
1. Humanization design.
2. Material is cold-rolled steel with anti-bacteria powder coating. Can be customized.
Arm Rest
1. Alleviate fatigue on operator’s armsÂ
2. Prevent air obstruction
3. Adjustable Height Range: 85~100mm
Formalin Fumigation Sterilizer Ammonium Hydrogen Carbonate Neutralizer
Sterilize the cabinet with formalin for 8 hours and neutralize the formalin with ammonium hydrogen carbonate for 8 hours.
Laboratory Chair
1. Material: Economic line-artificial leather
2. Backrest Height: 45cm
3. Height Range: 43~57cm